PG-2000 CENTRAL ACCESS PANEL (CAP) For EC-GOLD TRANSMITTERS User Manual Technical Support Continental North America To
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 8 - The bottom line displays the common alarm status. Based on the current alarm state, “OK”, “Low
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 9 - Each zone may have 2 mA modules: one for the max ppm in the zone and the other for the average p
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 10 - 3.6 SET ALARM VALUES, DELAYS AND RELAY MAP 1. Press the CONT key then press 1 for Gas Alarms
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 11 - 4. After selecting the desired gas by pressing 1 in step above, enter the high and low thresho
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 12 - 4.0 MISCELANEOUS SETUP Each remote EC Gold transmitter may be individually setup and calibrated
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 13 - 3. At the prompt, enter the address number of the desired EC Gold transmitter to be calibrated
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 14 - 5.0 BMCS ACCESS The Enmet CAP's (Central Access Panels or Scanners) may be accessed via an
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 15 - 6.0 SETTINGS SHEET Checked by Model Number Serial Number Hardware Rev. Software Rev. The f
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 16 - Code 23 = Unused Low Alarm high threshold Low Alarm low threshold High Alarm high thres
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 17 - Relay Mapping (Circles specifys the factory setting of "YES" as per job specification
Toxic Gas Monitor For Ventilation ControlThe PG-2000 offers an intelligent solution togas monitoring and ventilation control. Morethan 30 years of gas
Arjay Engineering Ltd. 2851 Brighton RoadOakville, OntarioCanadaL6H 6C9tel ++1 905-829-2418fax++1 905-829-4701N. America 1-800-387-9487email arjay@a
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 2 - TABLE OF CONTENTS 1.0 INSTRUMENT OVERVIEW ...
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 3 - 1.0 INSTRUMENT OVERVIEW 1.1 FEATURES • Automatic scanning of up to 80 EC Gold network sensors.
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 4 - For each zone, the maximum and average ppm values are calculated and transmitted on optional 4-2
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 5 - 1.3 SPECIFICATIONS OPERATION The CAP can access a maximum of 80 EC Gold transmitters assigne
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 6 - 2.0 INSTALLATION See drawings at back of manual. 3.0 STARTUP AND CONFIGURATION Figure 3.0 3.1
Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 7 - 3.3 DISPLAY SCREENS After powerup, and the initial startup screen has been displayed for about 3